v Follow the suggested actions in the order in which they are listed in the Action column until the problemis solved.v See Chapter 4, “Parts listing, System x3250 M3 Types 4251, 4252, and 4261,” on page 119 to determinewhich components are customer replaceable units (CRU) and which components are field replaceableunits (FRU).v If an action step is preceded by “(Trained service technician only),” that step must be performed only by atrained service technician.v Go to the IBM support website at http://www.ibm.com/systems/support/ to check for technical information,hints, tips, and new device drivers or to submit a request for information.Error code Description Action005100A No usable memory detected. 1. Make sure that the server contains DIMMs.2. Reseat the DIMMs.3. Install DIMMs in the correct sequence (see“Installing a memory module” on page 152).4. Clear CMOS memory to re-enable all the memoryconnectors (see Table 2 on page 16).0058001 PFA threshold exceeded 1. Update the server firmware to the latest level (see“Updating the firmware” on page 193).2. Reseat the DIMMs and run the memory test (see“Running the diagnostic programs” on page 78).3. Replace the failing DIMM, which is indicated by alit LED on the system board.0058007 DIMM population is unsupported. 1. Make sure the installed DIMMs follow thepopulation rules and sequence described in“Installing a memory module” on page 152.2. Reseat the DIMMs, and then restart the server.3. Remove the lowest-numbered DIMM pair of thosethat are identified and replace it with an identicalpair of known good DIMMs, then restart theserver.4. Return the removed DIMMs, one pair at a time, totheir original connectors, restarting the server aftereach pair, until a pair fails. Replace the DIMMs inthe failed pair with identical known good DIMMs,restarting the server after each DIMM is installed.Replace the failed DIMM. Repeat this step untilyou have tested all removed DIMMs.5. (Trained service technician only) Replace thesystem board.0058008 DIMM failed memory test. 1. Reseat the DIMMs, and then restart the server.2. Replace the following components one at a time,in the order shown, then restart the server aftereach:a. DIMMb. (Trained service technician only) Systemboard00580A4 Memory population changed. Information only. Memory has been added, moved, orchanged.Chapter 3. Diagnostics 27