Section: 9IDS X64 Installer Manual 700-398-02D Issued August 2010 33Table 11: Number of Digits DataCode Old four-digit code New six-digit codeInstaller Code 9999 999999Maintenance Code 8888 888888Master User Code 1 1234 123456User Codes 2-128 XXXX XXXX00[INSTALLER CODE] [*] [2] [3] [*] [NUMBER OF DIGITS] [*]The valid data range is either 4 or 6.LOCATION 24 Number of Account Code Digits (default = 4)This location sets the account code length to either 4 or 6 digits. If the length of your accountcodes is 4 digits and then they are changed to 6 digits, the last two digits will be set to 0.[INSTALLER CODE] [*] [2] [4] [*] [NUMBER OF DIGITS] [*]The valid data range is: 4 or 6.9.3 Daylight SavingsLOCATION 25 Month to Start Daylight Saving (default = 1)Select the month for Daylight Saving to commence, as per Table 12.Table 12: Month DataValue Month Value Month0 Disabled 7 July1 January 8 August2 February 9 September3 March 10 October4 April 11 November5 May 12 December6 June[INSTALLER CODE] [*] [2] [5] [*] [MONTH] [*]The valid data range: 1 – 12, with 0 to disable.NOTE:If this location is disabled, then by default, locations 26 and 27 will also be disabled. This means thateven if you put values into locations 26 and 27, daylight savings will not commence.