Section: 9IDS X64 Installer Manual 700-398-02D Issued August 2010 71Table 34: Output Actions DataValue Output Action00 Set Output High (Set)01 Set Output Low (Reset)02 Pulse Output High03 Pulse Output LowTable 35 lists the default output and action for locations 390-414.Table 35: Default Programmable Events DataLoc Event DefaultOutputDefaultAction390 Close Programmable Output Event Output 3 [03] Set High [00]391 Stay Close Programmable Output Event Disabled [00]392 Open Programmable Output Event Output 3 [03] Set Low [01]393 Cancel Programmable Output Event Disabled [00]394 Alarm Restoral Programmable Output Event Disabled [00]395 Bypass Programmable Output Event Disabled [00]396 Forced Arm Programmable Output Event Disabled [00]397 Zone Tamper Programmable Output Event Disabled [00]398 Zone Tamper Restoral Programmable Output Event Disabled [00]399 Zone Shutdown Programmable Output Event Disabled [00]400 Zone Shutdown Restoral Programmable Output Event Disabled [00]401 Keypad Panic Programmable Output Event Output 1 [01] Pulse High [02]402 Keypad Fire Programmable Output Event Output 4 [04] Pulse High [02]403 Keypad Medical Programmable Output Event Output 5 [05] Pulse High [02]404 Keypad Lockout Programmable Output Event Disabled [00]405 Duress Programmable Output Event Output 1 [01] Pulse High [02]406 Verifies Alarm Programmable Output Event Disabled [00]407 Burglary Programmable Output Event Output 2 [02] Pulse High [02]408 Panic Programmable Output Event Output 1 [01] Pulse High [02]409 Fire Programmable Output Event (Refer to Table 5) Disabled [00]410 Tamper Zone Programmable Output Event Disabled [00]Table 36: Default Programmable Events Data with no Default ActionLoc Event DefaultOutput411 Siren Programmable Output Event Disabled [00]412 Strobe Programmable Output Event Disabled [00]413 Chime Programmable Output Event Disabled [00]414 Arm Follow Programmable Output Event Disabled [00]NOTE:Once a programmable output has been enabled, the default action will be Pulse High [02].