Section: 9IDS X64 Installer Manual 700-398-02D Issued August 2010729.15.3 Zone Programmable Output EventsThe following locations are used to program the various zone outputs.LOCATIONS 415 - 422 Zone Programmable Output EventsAn output can be assigned to a zone such that in the event of that zone causing an alarm condition, thechosen output performs the selected option. A list of available actions and their corresponding values isshown in Table 35.Regardless of the action selected for a particular output, if it is programmed to clear on disarming of thepanel (locations 380-389), the output will revert to clear (set low) after any partition disarmed.Each location represents a set of 8 zones: Location 415 is zones 1-8 Location 416 is zones 9-16 Location 417 is zones 17-24 Location 418 is zones 25-32 Location 419 is zones 33-40 Location 420 is zones 41-48 Location 421 is zones 49-56 Location 422 is zones 57-64Enter a 4-digit output and action for each of the 8 zones and program as 32-digit strings,followed by the [*] key.[INSTALLER CODE] [*] [4] [1] [5] [*] [ZONE NO.] [*] [OUTPUT] [ACTION] [*]Refer to section 8.2 Programming Standard Locations to see how to scroll through data in a locationusing the [*] key.LOCATIONS 423 - 426 Global Programmable Output EventsThese locations allow you to configure the global programmable output events. Refer to Table 37 to viewthe programmable output events per location. LEDs 1-8 represent the output number, and LEDs 9-16 represent the action. Once aprogrammable output has been enabled, the default action will be Pulse High [02]. If dual reporting is enabled, an output allocated to the dual reporting programmable output eventwill be set when the panel dials the second phone number, and cleared when it hangs up at theend of the transmission. This output follows the hook relay. It may be used to trigger switchingfrom the telephone line to a radio transmitter. There is no output action for the fire sensor power and dual reporting programmable outputevents.