Section: 9IDS X64 Installer Manual 700-398-02D Issued August 2010789.16 Event Reporting Options - AdvancedThe following locations from 501-588 enable disable the reporting of events programmed into locations300-373. If a reporting code has been programmed, and the reporting of that code is not enabled here –then the reporting code will not report.LOCATIONS 501 – 564 Split Reporting Zones 1 - 64Locations 501 (zone 1) – 564 (zone 64) represent a bitmap of 64 split reporting zone locations.Table 40: Split Reporting Zones Bitmap DataLED On/Off Action LED On/Off Reporting Pair1ON Enable zone alarm reporting9ON Telephone module 2OFF Disable zone alarm reporting OFF Telephone module 12ON Enable zone alarm restorereporting 10ON Telephone module 2OFF Disable zone alarm restorereporting OFF Telephone module 13ON Enable zone bypassreporting 11ON Telephone module 2OFF Disable zone bypassreporting OFF Telephone module 14ON Enable zone force armreporting 12ON Telephone module 2OFF Disable zone force armreporting OFF Telephone module 15ON Enable zone tamperreporting 13ON Telephone module 2OFF Disable zone tamperreporting OFF Telephone module 16ON Enable zone tamper restorereporting 14ON Telephone module 2OFF Disable zone tamper restorereporting OFF Telephone module 17ON Enable zone swingershutdown reporting 15ON Telephone module 2OFF Disable zone swingershutdown reporting OFF Telephone module 18ON Enable zone swingershutdown restore reporting 16ON Telephone module 2OFF Disable zone swingershutdown restore reporting OFF Telephone module 1Default values are shadedNOTE:See section 9.5 Communications Setup - Advanced.