Section: 9IDS X64 Installer Manual 700-398-02D Issued August 2010 35The valid data range is: 1 – 7.LOCATION 30 Week of Month to End Daylight Saving (default = 1)Select the week of the month as per Table 14, to disable Daylight Saving.[INSTALLER CODE] [*] [3] [0] [*] [WEEK] [*]The valid data range is: 1 – 5.LOCATION 31 Daylight Saving Time Offset (default = 60)Enter the daylight saving time offset that will be sued while daylight saving is enabled. Refer tolocations 25-30.[INSTALLER CODE] [*] [3] [1] [*] [DAYLIGHT SAVING TIME OFFSET] [*]The valid data range is: 0 – 250.9.4 Miscellaneous - AdvancedLOCATION 32 Auto Test Report Interval (default = 1)The value programmed into this location determines the duration of time between AutomaticSystem Tests. Input the value as per Table 15.Table 15: Auto Test Interval DataValue Time Period Value Time Period0 Report every hour 8 Every eight days1 Report daily 9 Every nine days2 Every two days 10 Every ten days3 Every three days 11 Every eleven days4 Every four days 12 Every twelve days5 Every five days 13 Every thirteen days6 Every six days 14 Every fourteen days7 Every seven days 15 Every fifteen days[INSTALLER CODE] [*] [3] [2] [*] [AUTO TEST REPORT INTERVAL] [*]The valid data range is: 0 – 15.LOCATION 33 Auto Test Time (default = 0010)Enter the time when the auto test will be reported. The format is [HHMM] based on a 24-hourclock. (All 4 digits must be entered.)[INSTALLER CODE] [*] [3] [3] [*] [HHMM] [*]The valid data range is: 00h00m – 23h59m.