Troubleshooting 8-23Errorcode Error message Recommended Action0B94 IPMB signal lines do not respond. All the functions other than the function ofaccessing to SMC through IPMB can be used.This is not a fatal error. Turn off the poweronce and then on again to restart the server. Ifthe error cannot be corrected, contact yourservice representative.0B95 BMC FRU device failure. All the commands and functions other than theFRU command and the EMP function can beused. This is not a fatal error. Turn off thepower once and then on again to restart theserver. If the error cannot be corrected,contact your service representative.0B96 BMC SDR Repository failure.0B97 BMC SEL device failure.0B98 BMC RAM test error.0B99 BMC Fatal hardware error.0B9A BMC not responding.0B9B Private I2C bus not responding.0B9C BMC internal exception.0B9D BMC A/D timeout error.0B9E SDR repository corrupt.0B9F SEL corrupt.Turn off the power once and then on again tostart the server. If the error cannot becorrected, contact your service representative.0BB0 SMBIOS - SROM data read error.0BB1 SMBIOS - SROM data checksum bad.Contact your service representative.0BC0 POST detected startup failure of 1stProcessor.0BC1 POST detected startup failure of 2ndProcessor.0BC2 POST detected startup failure of 3rdProcessor.0BC3 POST detected startup failure of 4thProcessor.Contact your service representative to replacethe processor.8120 Unsupported DIMM detected in DIMMgroup #1.8121 Unsupported DIMM detected in DIMMgroup #2.8122 Unsupported DIMM detected in DIMMgroup #3.8123 Unsupported DIMM detected in DIMMgroup #4.8124 Unsupported DIMM detected in DIMMgroup #5.8125 Unsupported DIMM detected in DIMMgroup #6.8126 Unsupported DIMM detected in DIMMgroup #7.8127 Unsupported DIMM detected in DIMMgroup #8.Contact your service representative to replacethe two DIMMs in the relevant group.