Troubleshooting 8-59Error Message for Battery for On-board RAID (MegaRAID ROMB)The battery is discharged and charged in a regular basis (every 30 days by the default). Thefollowing error message may be registered in event log (application log), however, it is not aproblem in operating the system. MegaRAID Storage Manager (MSM) logController ID:x Battery is discharging. Application event logEvent Source: MR_MONITOREvent Type: WarningEvent ID: 148Description: Controller ID:x Battery is discharging. MegaRAID Storage Manager (MSM) logController ID:x BBU disables; changing WB logical drives to WT. Application event logEvent Source: MR_MONITOREvent Type: WarningEvent ID: 195Description: Controller ID:x BBU disables; changing WB logical drives to WT.The battery is charged and discharged when it is replaced or at installation of the system. Thefollowing error message may be registered in event log (application log), however, it is not aproblem in operating the system. MegaRAID Storage Manager (MSM) logController ID:x Battery requires reconditioning – please initiate a LEARN cycle. Application event logEvent Source: MR_MONITOREvent Type: WarningEvent ID: 253Description: Controller ID:x Battery requires reconditioning – please initiate a LEARNcycle.