Program 20 : System Option Setup20-45 : Remote Watch SetupLevel:INDescriptionUse Program 20-45 : Remote Watch Setup to defines the remote watch.Input DataTerminal Number 1 ~ 6ItemNo.Item Input Data Description Default01 Ring Terminal for Re-mote InspectionExtension Number (Upto 8 digits)Extension number for Remote Inspection No Setting02 Ring Time Setting 0000 ~ 2359 Ringing start time for Inspected Extension 000003 Ring Timer 0 ~ 60 Ringing continue time for inspected exten-sion004 Auto Dial NumberArea Setting0 ~ 999 Speed dial number when detect no answerat extension and make emergency call005 VRS Message for An-swer0 ~ 100 VRS message number when inspected ex-tension answered006 VRS Message for Au-to Dial0 ~ 100 VRS message number when emergencycall destination answered.007 Time of Repeat AutoDial0 ~ 255 Repeat number for making emergencycall.008 Auto Dial CallingTime0 ~ 3600 Calling continue time when making emer-gency call.009 Interval of Auto Dial 0 ~ 3600 0ConditionsNoneFeature Cross ReferenceNoneSL1100 ISSUE 4.02-220 Program 20 : System Option SetupProgram20