Program 80 : Basic Hardware Setup for System80-04 : Call Progress Tone Detector SetupLevel:MFDescriptionUse Program 80-04 : Call Progress Tone Detector Setup to define the various levels and timers forthe Call Progress Tone Detector.Tone Detector Type :• 1 = Dial Tone for Trunk• 2 = Busy Tone for Trunk• 3 = Ring Back Tone for Trunk• 4 = Special Busy Tone for Trunk• 5 = Special Ring Back Tone for TrunkInput DataTone Detector Type Number 1 = Dial Tone for Trunk2 = Busy Tone for Trunk3 = Ring Back Tone for Trunk4 = Special Busy Tone for Trunk5 = Special Ring Back Tone for TrunkItemNo.Item Input Data Default01 Detection Level 0 = 0 dBm ~ - 25 dBm1 = - 5 dBm ~ - 30 dBm2 = - 10 dBm ~ - 35 dBm3 = - 15 dBm ~ - 40 dBm4 = - 20 dBm ~ - 45 dBm5 = - 25 dBm ~ - 50 dBm6 = - 30 dBm ~ - 55 dBmRefer below02 Min. Detection Level 0 ~ 150 = - 10 dBm (0) ~ - 25 dBm (15)1 = - 15 dBm (0) ~ - 30 dBm (15)2 = - 20 dBm (0) ~ - 35 dBm (15)3 = - 25 dBm (0) ~ - 40 dBm (15)4 = - 30 dBm (0) ~ - 45 dBm (15)5 = - 35 dBm (0) ~ - 50 dBm (15)6 = - 40 dBm (0) ~ - 55 dBm (15)Refer below03 S/N Ratio 0 ~ 4 (0 dB ~ - 20 dB) Refer below04 No Tone Time 0 ~ 255 (30 + 30 ~ 7680 ms)(0 = not detect)1 ~ 255 = 60 ~ 7680 msThe formula is 30 + 30NWhen set to N = 1, it means 30 + 30 * 1 = 60.When set to N = 255, it means 30 + 30 * 255 =7680.Refer below05 Pulse Count 1 ~ 255 Refer below06 ON Minimum Time 1 ~ 255 (30 + 30 ~ 7680 ms) Refer below07 ON Maximum Time 0 ~ 255 (30 + 30 ~ 7680 ms) Refer belowSL1100 ISSUE 4.02-456 Program 80 : Basic Hardware Setup for SystemProgram80