Program 81 : Basic Hardware Setup for Trunk81-08 : T1 Trunk Timer SetupLevel:INDescriptionUse Program 81-08 : T1 Trunk Timer Setup to define the basic timer setting of each T1 Trunk type.Input DataItemNo.Item Input Data Default01 Answer Signal Detection Time(Loop)1 ~ 250 (4 ms ~ 1000 ms) 15 (60 ms)02 Answer Signal Detection Time(Ground)1 ~ 250 (4 ms ~ 1000 ms) 15 (60 ms)03 Answer Signal Detection Time(DID)1 ~ 250 (4 ms ~ 1000 ms) 15 (60 ms)04 Answer Signal Detection Time(E&M)1 ~ 250 (4 ms ~ 1000 ms) 15 (60 ms)05 Answer Signal Detection Time(OPX)1 ~ 250 (4 ms ~ 1000 ms) 15 (60 ms)06 Clear Signal Detection Time (Loop) 1 ~ 255 (100 ms ~ 25500 ms) 6 (600 ms)07 Clear Signal Detection Time(Ground)1 ~ 255 (100 ms ~ 25500 ms) 6 (600 ms)08 Clear Signal Detection Time (DID) 1 ~ 255 (100 ms ~ 25500 ms) 6 (600 ms)09 Answer Signal Detection Time(E&M)1 ~ 255 (100 ms ~ 25500 ms) 6 (600 ms)10 Clear Signal Detection Time (OPX) 1 ~ 255 (100 ms ~ 25500 ms) 6 (600 ms)11 Ringing Signal Detection Time(Loop)1 ~ 250 (8 ms ~ 2000 ms) 10 (80 ms)12 Ringing Signal Detection Time(Ground)1 ~ 250 (8 ms ~ 2000 ms) 10 (80 ms)13 Ringing Signal Detection Time(DID)1 ~ 250 (8 ms ~ 2000 ms) 10 (80 ms)14 Ringing Signal Detection Time(E&M)1 ~ 250 (8 ms ~ 2000 ms) 10 (80 ms)15 Ringing Signal Detection Time(OPX)1 ~ 250 (8 ms ~ 2000 ms) 10 (80 ms)16 Ringing Signal Stop DetectionTime (Loop)1 ~ 255 (100 ms ~ 25500 ms) 50 (5000 ms)17 Ringing Signal Stop DetectionTime (Ground)1 ~ 255 (100 ms ~ 25500 ms) 50 (5000 ms)18 Ringing Signal Stop DetectionTime (DID)1 ~ 255 (100 ms ~ 25500 ms) 50 (5000 ms)19 Ringing Signal Stop DetectionTime (E&M)1 ~ 255 (100 ms ~ 25500 ms) 50 (5000 ms)SL1100 ISSUE 4.02-472 Program 81 : Basic Hardware Setup for TrunkProgram81