Program 80 : Basic Hardware Setup for System80-01 : Service Tone SetupLevel:INDescriptionUse Program 80-01 : Service Tone Setup to define up to 64 Service Tones. Each service tone isdefined by the combination of 32 Basic Tones.Input DataService Tone Number 01 ~ 64ItemNo.Item Input Data Default01 Repeat Count 0 ~ 255 (0 = Endless) Refer belowUnit Number 1 ~ 8ItemNo.Item Input Data Default02 Basic Tone Number 0 ~ 33(0 = No Tone)(33 = Default Time Slot)Refer below03 Duration Count 0 ~ 255 (0, 100 ~ 25500 ms) Refer below04 Gain Level (dB) 0 ~ 63 (- 15.5 ~ + 15.5) Refer belowTable 2-13 Basic TonesBasic Tone No. Frequency (Hz) Level (dB)01 400 - 1302 520 - 1303 580 - 1304 660 - 1305 700 - 1306 800 - 1307 880 - 1308 1050 - 1309 350 / 440 - 16 / - 1610 440 / 480 - 16 / - 1611 480 / 620 - 21 / - 2112 440 -1613 -- Reserve -- -14 520 / 650 -19 / -13SL1100 ISSUE 4.02-448 Program 80 : Basic Hardware Setup for SystemProgram80