Program 82 : Basic Hardware Setup forExtension82-12 : OPX Initial Data SetupLevel:INDescriptionUse Program 82-12 : OPX Initial Data Setup to define the various initial data for OPX packages.Input DataItemNo.Item Input Data Description Default01 Bounce Protect Time 0 = No setting1 ~ 15 = 100 ms ~ 1.5secSpecify a time for detection of a valid off-Hook indication that is long enough to pre-vent an unintentional bounce of the receiv-er from being detected as a new Off-Hookindication from a single line telephone.3(300 ms)02 HookFlash Start Time 0 = 40 ms1 ~ 15 = 90 ms ~ 790 msSpecify the minimum hookflash time froma single line telephone or analog VoiceMail system before it is detected as the be-ginning of a valid hookflash.5(290 ms)03 HookFlash End Time 0 = HST + 0 ms1 ~ 15 = HST + 100 ms~ HST + 1500 ms(HST = Hookflash StartTime)Specify the maximum hookflash durationfrom a single line telephone to receive asecond dial tone.7(990 ms)ConditionsNoneFeature Cross ReferenceNoneISSUE 4.0 SL1100Programming Manual 2-489Program82