106Readout data of the measurement result of output powerSTX PWM A[Readout data format] [Measurement value of laser power][Initial ratio of laser power] [Determination]10-byte(Check sum) DelimiterName Data length[byte] Description RemarksReadout dataformat 1“0”: Measurement value of laserpower“1”: Correction dataSpecifies the readout data format.When the output power measurement results is readout, this data will be “0”.Measurementvalue of laserpower5 “000.0”–“xxx.x” [W]Indicates power measurement results.At the automatic/manual power correction mode,indicates the power value after the correction.Initial ratio oflaser power 3“000”–“xxx” [%](When laser power setting valueis not 100.0, and after the powercorrection, this data is always“100”.)This result is valid only in the measurement resultreadout just after the start point of the outputpower measurement with the setting power 100.0.Indicates initial ratio.Determination 1“0”: Correct (When laserpower setting value is not100.0, and after the powercorrection, this data isalways “0”.)“1”: Lower than the low powerdetect.Indicates whether or not the power measurementresult is lower than the value set in “Low PowerDetect Level”.This result is valid only in the measurement resultreadout just after the power measurement with thesetting power 100.0.Readout data of the correction resultsSTX PWM A[Readout data format] [Power correction ratio][Correction date] [Total laser radiation time]27-byte(Check sum) DelimiterName Data length[byte] Description RemarksReadout dataformat 1 “0”: Measurement result“1”: Correction dataSpecifies the readout data format.When the correction data is read out, this data willbe “1”.Power correctionratio 3 “050”–“200” [%] When the power correction has not been performed,it becomes “000”.Correction date 14When the time is 15:00:00of January 15, 2011,“20110115150000” appears.When the power correction has not been performed,“00000000000000”Total laserradiation time 9 “0000000.0”–“1000000.0” [h]ME-LPMSZ-SR-9