134. With DIP switch No. 5, select the setting method of the remotemode.DIP switch No. 5 Setting method of remote modeON Use the input signal of REMOTE IN (X5) on I/O terminal.OFF(initial setting) Use the remote switch on the front of the controller.Reference• When DIP switch No. 5 is ON, the remote switch on the controller is not available.5. When DIP switch No. 5 is OFF, select the remote mode state atpowered ON with DIP switch No. 6.DIP switch No. 6 Remote mode state at powered ONON Starts up with remote mode ONOFF (initial setting) Starts up with remote mode OFFReference• When DIP switch No. 5 is ON, keep DIP switch No. 6 OFF.• When DIP switch No. 6 is ON, “X5: REMOTE IN” signal on I/O terminal is not available.CAUTION • If the DIP switch No. 5 or No. 6 are used while turned on, construct a systemfor re-pumping the laser manually as safety protection measures after the stopof the laser radiation due to an emergency stop or an interlock.6. If you want to use the command format compatible with the former models of LP-F10/LP-F10Wseries, select the command mode using DIP switch No. 7 and No. 8.Standard Mode LP-F10 Mode LP-F10W ModeNo. 7: OFFNo. 8: OFFNo. 7: ONNo. 8: OFFNo. 7: OFFNo. 8: ONNotice• Even with the use of LP-F10/F10W mode, there is a difference in communication processing time and I/O operationtiming between older model of LP-F10/LP-F10W and LP-M/LP-S/LP-Z series.7. Install the DIP switch cover to the controller.Notice• A plastic cover is installed on the DIP switch. Install this cover always to avoid the dust penetration to the controller.8. Turn ON the power of laser marker.ME-LPMSZ-SR-9