625. For GS1 DataBar Standard & Truncated, GS1 DataBar Limited and GS1 DataBar Expanded (Includingwhen these codes are 1D part of the composite code.)Data length : 52-byte (LP-Mxxx / LP-Sxxx / LP-Zxxx), 49-byte (LP-SxxxW)Name Data length[byte] Description RemarksBar code No. 2 “00”–“15”Layer No. 2 “00”–“15”Code type 2“30”: GS1 DataBar STD & Truncated“33”: GS1 DataBar Limited“34”: GS1 DataBar Expanded“40”: GS1 DataBar STD & Truncated CC-A“43”: GS1 DataBar Limited CC-A“44”: GS1 DataBar Expanded CC-A“50”: GS1 DataBar STD & Truncated CC-B“53”: GS1 DataBar Limited CC-B“54”: GS1 DataBar Expanded CC-BHuman readable text 1 “0”: Invalid“1”: ValidInversion 1“0”: Do not invert“1”: Invert“2”: Invert (with guard)Bar code height 7Model type* Setting range [mm]LP-Sxx0(W) “001.000”–“090.000”LP-Sxx5(W) “001.000”–“160.000”LP-Sxx2 “001.000”–“055.000”LP-Mxx0/LP-Zxx0 “001.000”–“120.000”LP-Mxx5 “001.000”–“220.000”LP-Mxx6/LP-Zxx6 “001.000”–“330.000”Module width 5 “0.050”–“1.000” [mm]X position 8Model type* Setting range [mm]LP-Sxx0(W) “-045.000”–“+045.000”LP-Sxx5(W) “-080.000”–“+080.000”LP-Sxx2 “-027.500”–“+027.500”LP-Mxx0/LP-Zxx0 “-060.000”–“+060.000”LP-Mxx5 “-110.000”–“+110.000”LP-Mxx6/LP-Zxx6 “-165.000”–“+165.000”Specifies the center coordinateof the code.Y position 8Tilt angle 7 “-180.00”–“+180.00” [°]Laser power correction 3 “000”–“999” [%] • The correction ratio iscalculated using the valueset at the laser condition as100%.• With LP-SxxxW type,nothing should be inputin Laser Pulse CycleCorrection.Scan speed correction 3 “001”–“999” [%](Laser pulse cyclecorrection) (3) “001”–“999” [%]* For the detail of the model type, refer to “Target laser marker” (P.4).ME-LPMSZ-SR-9