109■ Low power detect level: PWL[Supported models: LP-M5xx/LP-M2xx/LP-Sxxx/LP-SxxxW]Sets thresholds for determination of whether the result of the power measurement or the power check is in the normalrange.Setting / Readout data the low power detect levelSTX PWL Subcommand[Low power detect level]2-byte (Check sum) DelimiterSub command is “S” at the time of setting and “A” for response data at the time of readout.Readout request out low power detect levelSTX PWL R (Check sum) DelimiterName Data length[byte] Description RemarksLow power detect level 2 “00”–“99” [%] When “00” is set, the detection is disabled.Reference• The setting changed by this command is saved without overwriting.■ Marking energy indicating: MEM[Supported models: LP-Mxxx/LP-Sxxx]Displays the measurement results of marking energy [mJ] and time on the setting screen when Test marking is finished.Setting / Readout data the marking energy indicatingSTX MEM Subcommand[Marking energy indicating]1-byte (Check sum) DelimiterSub command is “S” at the time of setting and “A” for response data at the time of readout.Readout request out marking energy indicatingSTX MEM R (Check sum) DelimiterName Data length[byte] Description RemarksMarking energy indicating 1 “0”: OFF“1”: ONSpecifies whether the display of the measurementresults of marking energy and time after TestMarking is enabled.Reference• Under the remote mode, the measurement results do not appear on the screen. If the “Marking status transmissionpermission (MST command)” is set to “Transmission permitted”, the measurement results of the marking energy aretransmitted after the marking operation.• The setting changed by this command is saved without overwriting.ME-LPMSZ-SR-9