43■ Guide LD display: GIDControls radiation of red guide laser for marking position confirmation.Setting of guide LD display:STX GID S [Guide laser type] [Scan speed] [Z offset]Max. 14-byte (Check sum) DelimiterName Data length[byte] Description RemarksGuide lasertype 1“0”: Display stop“1”: Marking area“2”: Marking character“3”: Work image display“4”: Dual pointerScan speed (5)Model type* Setting range [mm/s]LP-Sxx0/LP-Sxx5/LP-Mxx0/LP-Mxx5/LP-Zxx0“00001”–“06000”LP-SxxxW/LP-Sxx2 “00001”–“03000”LP-Mxx6/LP-Zxx6 “00001”–“04000”The moving speed of the guide indicationis indicated. (omissible)Z offset(Effective onlyLP-M / LP-Zseries)(8)Model type* Setting range [mm]LP-Sxx(W) “+000.000” (fixed)LP-Mxxx “-022.000”–“+022.000”LP-Zxxx “-025.000”–”+025.000”• LP-Sxxx/LP-SxxxW:As this item is not available for the LP-Sseries, set to “+000.000” or no data.• LP-Mxxx / LP-Zxxx:Being effective when Guide laser typeis “1”: Marking Area or “4”: Dual Pointer,it indicates Z displacement of guidedisplay in comparison to the base workdistance. (omissible)* For the detail of the model type, refer to “Target laser marker” (P.4).Reference• Omit the Z offset too if omitting the scan speed setting.• This command is available only when the DIP switch No. 2 on the rear side of the controller is ON.• You can start the guide laser radiation when the internal shutter is closed or when the “command reception mode ON” isset by Command reception permission (MKM) command.• The internal shutter is automatically opened and closed at the time of start and stop of the radiation.• The guide laser stops automatically after about one minute even if the stop request command was not sent. At this timethe internal shutter is automatically closed.• After the guide laser emission with “command reception mode ON” status by MKM command, the shutter is openedwhen the “command reception mode OFF” is set by MKM command.• Do not execute any other operation including the shutter opening/closing and sending MKM command while the guidelaser is emitted.ME-LPMSZ-SR-9