96■ Marking ON/OFF by layer: LMSSpecifies whether mark the setting data or not by each layer No.Without this setting, the data in all layers in a file is marked. If there is a layer that should not be marked, send thiscommand and set it to mark off.Setting / Readout data of marking on/off by layerSTX LMS Subcommand[Marking on/off by layer]16-byte (Check sum) DelimiterSub command is “S” at the time of setting and “A” for response data at the time of readout.Readout request of marking on/off by layerSTX LMS R (Check sum) DelimiterName Data length[byte] Description RemarksMarking on/off bylayer 16Send “0” or “1” for 16 layers.“0”: Mark OFF“1”: Mark ONMarking on/off setting for all layers(layer No. 0 to No. 15).In the order of the layer No. from 0 to 15, send “0:mark off” or “1: mark on” for every 16 layers.Even not all layers are used, send 16 digits with “0” or“1”.Data example: Setting for marking off to the layer No.2 and 3, and no data in layer No. 4 to 16.“1100111111111111” or “1100000000000000”Reference• If there is a layer desired not to be marked, send this command every time when the file No. is changed and whenremote mode is turned on.• When the laser marker power or the remote mode is turned off, or when the file No. is changed, this setting is clearedand all layers are set to “mark on”.• This setting is not saved to the laser marker.• The data in a layer set to mark off is not scanned by guide laser.• This setting can not be confirmed in the marking image screen.• Regardless of this setting, when the function of rank, external offset, serial data marking or serial offset is used in thefile, the external input for these data is required.ME-LPMSZ-SR-9