19[Before Use]Before UseMounting Direction and Space Requirements• Allow enough space to ensure enough cooling.• Install fans to provide a uniform distribution of temperature in the control box.• Observe the environmental requirements for the control box, mentioned in the previous page.This driver has a cooling fan in its bottom and a mounting face.To install the driver, ensure that there is enough space around the inlet and outlet ports so as not to preventintake and exhaust of the fans.x1x3x4x5x6STATUS ALM CODEx1x3x4x5x6STATUS ALM CODEx1x3x4x5x6STATUS ALM CODEx1x3x4x5x6STATUS ALM CODEFanDriver ExhaustDirectionFanDriver ExhaustDirectionDriver ExhaustDirectionDriver ExhaustDirectionDriver IntakeDirectionDriver IntakeDirectionDriver IntakeDirectionDriver IntakeDirectionmin.100 mmmin.40 mmmin.40 mmmin.10 mmmin.10 mmmin.10 mmmin.100 mmPart where DINrail is mountedDIN railWith rail stoppushed inHook the upper side of DIN railmounting part on the DIN rail.With the rail stop released, pull out thelower part of the driver to the near side.By lifting the driver, you can remove itfrom the DIN rail.Pull out the lower partof the driver to thenear side.Press lightly the lower part ofthe main body of driver.Press lightly.Ensure that the rail stophas been pushed in.Driver mounted to DIN rail(4) Removing from DIN RailBuy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com