154 Maintenance and Inspections: Warning System5. Image Sequence ErrorDisplay windowindication“E-40” appears in the time code display field.WARNING lamp Blinks 4 times per second.Tally lamp Blinks 4 times per second while recordingcontinues.Viewfinder The REC WARNING indicator lights up.Warning tone Beeps 4 times per second.WarningdescriptionThere are abnormal conditions in the imagesequence of the 24P, 30P, or 25P mode.Recording/playbackoperationImages can be recorded and played back,but some frames may be dropped or thesequences of TC and UB may shift.CountermeasuresConfirm the recording/playback operationafter turning OFF the power supply once andthen turning it on again. If the error is notcorrected after executing this procedure,contact the dealer.6. Corruption of Standard SignalDisplay windowindication“E-40” appears in the time code display field.WARNING lamp Blinks 4 times per second.Tally lamp Blinks 4 times per second.Viewfinder The TEMPORARY PAUSE indicator lights up.Warning tone Beeps 4 times per second while recordingcontinues.WarningdescriptionCorruption in the input signals from thestandard GENLOCK IN and SDI INconnectors means correct recording is notpossible, and this has stopped. The clip willbe divided.Recording/playbackoperationWhen the signal returns to normal, recordingwill automatically start again. However, thiswill not automatically start when inINTERVAL REC mode or LOOP REC mode.CountermeasuresPlease check the input signal from theGENLOCK IN connector or SDI IN connector.If errors continue, please contact your dealer.7. Recording ErrorDisplay windowindication“00:00:00:11” appears in the time code displayfield. Even after recording is stopped, thisdisplay continues to blink until the nextoperation is performed.WARNING lamp Blinks 4 times per second while recordingcontinues.Tally lamp Blinks 4 times per second while recordingcontinues.Viewfinder The REC WARNING indicator lights up.Warning tone Beeps 4 times per second while recordingcontinues.WarningdescriptionThis indicates a failure either in the P2 cardrecording or the recording circuit.Recording/playbackoperationThe recording may stop or continue.CountermeasuresRestart recording. Or, turn the power OFF andturn it ON again, before starting recording. Ifthe recording cannot be performed normally,change the P2 card.8. Number of Clips ExceededDisplay windowindication“00:00:00:11” appears in the time code displayfield. Even after recording is stopped, thisdisplay continues to blink until the nextoperation is performed.WARNING lamp Blinks 4 times per second while recordingcontinues.Tally lamp Blinks 4 times per second while recordingcontinues.Viewfinder The OVER MAX# CLIPS indicator lights up.Warning tone Beeps 4 times per second while recordingcontinues.WarningdescriptionThis is displayed when attempting to recordclips where the total quantity exceeds theupper limit (1000 pieces) for a single P2 card.Recording/playbackoperationCannot record. Stops while recording.Countermeasures Insert a new P2 card or delete the unwantedclips in the P2 card.9. Low Wireless Signal ReceptionDisplay windowindication No display.WARNING lamp Blinks 4 times per second. (During pause andrecording)Tally lamp Blinks 4 times per second while recordingcontinues.Viewfinder The WIRELESS RF indicator lights up whilerecording continues.Warning tone Beeps 4 times per second while recordingcontinues.WarningdescriptionThis error indicates poor wireless audioreception conditions.Recording/playbackoperationContinues to operate without receiving thewireless microphone signal.Countermeasures Check the microphone power supply and thereception status of the wireless receiver.10. Battery Nearly EmptyDisplay windowindicationOne of the bars in the battery remainingindicator starts blinking.WARNING lamp Blinks once per second.Tally lamp Blinks once per second.Viewfinder The BATT LED blinks.Warning tone Beeps 4 times per second.Warningdescription The battery is about to run out.Recording/playbackoperationContinues to operate.Countermeasures Replace the battery as required.