HL-G1 User's Manual 5.2 Serial Commands955.2.1.2 Write Command (Format 1)Request command from the external deviceUse this command to write 5-digit values for function settings in the sensor.1 Number of the sensor to which the request is sent2 Command sent to the sensor. Select the appropriate command from the command tables (see page104).3 Block of data to be written to the sensor. 1 character for +/- and 5 characters for integers (zeros are notsuppressed).4 BCCNormal response from the sensorIf the command can be interpreted correctly by the sensor, this is the normal response. If thesensor cannot interpret the command correctly, the sensor returns an error code (see page102).1 Sensor number2 Command the sensor has received.3 BCC EXAMPLEUse this command to set the average function to 256 times for sensor 2.A normal response from the sensor would be as follows:5.2.1.3 Write Command (Format 2)Request command from the external deviceUse this command to write 7-digit values for function settings in the sensor.Rugghölzli 2CH - 5453 BusslingenTel. +41 (0)56 222 38 18Fax +41 (0)56 222 10 12mailbox@sentronic.comwww.sentronic.comProdukte, Support und ServiceSENTRONIC AG