Functions HL-G1 User's Manual40Output functionsFunction name Description Default setting Type of settingJudgment outputselection (see page60)Selects the output operation ofOUT1 – OUT3.2-state (OUT1 andOUT2) Sets threshold a +(detection range) Sets threshold b -(detection range)Displacement judg-ment (see page 62) Sets hysteresis +(0.2% of setting range)Judgment outputOFF delay (see page63)Delays the switching OFF of thejudgment output. OFFMeasurement valuedisplay on panel (seepage 65)Sets the number of rightmost digitsto be turned OFF on the digital dis-play.SET 1Individual setting permemoryAnalog functionsFunction name Description Default setting Type of settingAnalog output selec-tion (see page 66)Selects the output type for the ana-log output: current or voltage. Output currentScales measurement value A. Negative measuringrangeScales current A. +4.000mAScales voltage a. 0.000VScales measurement B. Positive measuringrangeScales current B. +20.000mAAnalog scaling (seepage 67)Scales voltage b. 10.000VIndividual setting permemoryAlarm functionsFunction name Description Default setting Type of settingAnalog output atalarm (see page 68)Sets the analog output behavior forwhen an alarm occurs. Hold previous valueDigital output atalarm (see page 69)Sets the digital output behavior forwhen an alarm occurs. Hold previous valueAlarm delay (seepage 70)Sets the number of measurementattempts to be made before analarm is output.8 timesIndividual setting permemoryRugghölzli 2CH - 5453 BusslingenTel. +41 (0)56 222 38 18Fax +41 (0)56 222 10 12mailbox@sentronic.comwww.sentronic.comProdukte, Support und ServiceSENTRONIC AG