HL-G1 User's Manual 4.4 Function Settings63 NOTE Threshold a needs to be larger than threshold b. However, if the user entersthe values the wrong way round, the sensor will automatically use the lowervalue as threshold b. The position of the decimal point varies with each model.4.4.4.3 Judgment Output OFF DelayDelays the switching OFF of the judgment output. NOTEThis function is useful when the judgment output needs to be transmitted to acontrol device, but changes too quickly.The bold table entry indicates the default setting.Setting Function Digital displayOFF Output according to the sampling cycle2ms Delays switching OFF the judgment output by 2ms.4ms Delays switching OFF the judgment output by 4ms.10ms Delays switching OFF the judgment output by 10ms.20ms Delays switching OFF the judgment output by 20ms.40ms Delays switching OFF the judgment output by 40ms.100ms Delays switching OFF the judgment output by100ms.HoldOnce the output has been switched ON, it will bekept on hold. To release an output kept on hold, youneed to input the reset signal.Rugghölzli 2CH - 5453 BusslingenTel. +41 (0)56 222 38 18Fax +41 (0)56 222 10 12mailbox@sentronic.comwww.sentronic.comProdukte, Support und ServiceSENTRONIC AG