Serial Communication via RS422/485 HL-G1 User's Manual100Normal response from the sensorIf the command can be interpreted correctly by the sensor, this is the normal response. If thesensor cannot interpret the command correctly, the sensor returns an error code (see page102).1 Sensor number2 Command the sensor has received.3 Measured value at start point. 1 character for +/- and 7 characters for integers (zeros are not sup-pressed).4 Differential data between one measurement value and the next until the end point is reached5 BCC EXAMPLEThe output of differential data as shown above would be transmitted if the sensormemory contained the following buffered measurement values:5.2.3.3 Read Buffered Data in Binary Format (Format 6)Request command from the external deviceUse this command to read the buffered data in binary format. Every measurement value in thesensor memory will be converted to binary format. The binary data is in 4 bytes beginning withthe lowest byte (little-endian).Measurement value Response fromsensorBinary DecimalStart point 0x0012D687 1234567Second point (start point + 1) 0x0012D71F 1234719Rugghölzli 2CH - 5453 BusslingenTel. +41 (0)56 222 38 18Fax +41 (0)56 222 10 12mailbox@sentronic.comwww.sentronic.comProdukte, Support und ServiceSENTRONIC AG