Inputs and Outputs HL-G1 User's Manual36Signal processing when more than one signal is ONThe table gives an overview of the system behavior when two signals occur at the same time.Signal = ON Behavior when timing signal is input(TM switches ON)Behavior when reset signal isinputSet-to-zero signal(ON/OFF)Sensor sets digital display to zero and out-puts the analog output selected for zero.These signals cannot occur simultane-ously as both are controlled by the MIinput (see page 26).Timing signal (TM) — The undefined status of the output datais kept on hold.Reset signal (MI signalON for 80ms)The output data status becomes undefinedand will remain undefined as long as TM isON.—Effect of the timing signal (TM)Depending on which analysis (measurement) mode you have selected, the timing signal has adifferent effect.Analysis mode System behaviorNormal When TM switches ON, the measurement value will be put on hold until TM switchesOFF.Peak / Valley When TM switches ON, the measurement value will be put on hold until TM switchesOFF. The peak / bottom value measured will be reset when TM switches OFF.Peak to peak When TM switches ON, the measurement value will be put on hold until TM switchesOFF. The measurement values will be set to zero when TM switches OFF.Rugghölzli 2CH - 5453 BusslingenTel. +41 (0)56 222 38 18Fax +41 (0)56 222 10 12mailbox@sentronic.comwww.sentronic.comProdukte, Support und ServiceSENTRONIC AG