HL-G1 User's Manual 4.3 Control Panel and Digital Display434.3 Control Panel and Digital DisplayThe measurement functions of the sensor are controlled via the control panel. The currentlyselected function or setting is shown in the digital display. NOTEIn order to ensure the performance of the system, allow a warm-up time of atleast 30 minutes after the system is turned ON.The control panel of the sensor head looks as shown below.1 2 3 4567LASER ALARM OUT 1 2 3ENTER SELECT1 Laser indicator (LASER)Lights up in green during laser emission.2 Alarm indicator (ALARM)Lights up in orange if an alarm occurs during measurement.3 OUT1/OUT2/OUT3 indicatorLights up in yellow during output4 [UP] keyUsed to select items or change numerical values.5 [DOWN] keyUsed to select items or change numerical values.6 Digital displayDisplays measurement values and system errors.7 [ENTER] keyUsed to access the functions and to confirm input.The digital display has the following properties and functions:Item Description Sensor type Digital display 30mm typeDecimal point The position of the decimal point varieswith each model. 50/80/120mm typeUndefined status ofoutput dataThe status of the output data may be-come undefined under certain conditions(see page 31).All typesRugghölzli 2CH - 5453 BusslingenTel. +41 (0)56 222 38 18Fax +41 (0)56 222 10 12mailbox@sentronic.comwww.sentronic.comProdukte, Support und ServiceSENTRONIC AG