HL-G1 User's Manual 4.4 Function Settings69When an alarm has occurred, for example when the sensor cannot measure the distancebecause it is too dark, the analog output can be kept on hold or set to a fixed value. The boldtable entry indicates the default setting.Setting Function Digital displayHold Holds the analog output immediately beforethe alarm.Fixed valueThe analog output depends on the setting for theanalog output (see page 66). 21.6mA for current output +11.000V for voltage output1.2.3. Procedure1. 2s2. 5x3.4.5. or to change the setting6. to confirm4.4.6.2 Digital Output at AlarmSets the digital output behavior for when an alarm occurs.When an alarm has occurred, for example when the sensor cannot measure the distancebecause it is too dark, the digital output can be kept on hold or set to a fixed value. The boldtable entry indicates the default setting.Setting Function Digital displayHold Holds the digital output immediately beforethe alarm.Fixed ValueOutputs a fixed value: 9.9999 (30mm type) 99.999 (50/80/120mm type)Rugghölzli 2CH - 5453 BusslingenTel. +41 (0)56 222 38 18Fax +41 (0)56 222 10 12mailbox@sentronic.comwww.sentronic.comProdukte, Support und ServiceSENTRONIC AG