HL-G1 User's Manual 4.4 Function Settings81Data bufferingThe data buffering works as shown below.HL-G1123456Make necessary settings for buffering.• Buffering mode• Buffering rate• Data amount to be accumulated• Trigger condition• Trigger delay• Trigger pointRead out the buffered data.• Last data point• Read buffered data• Read differential data• Read binary dataStart buffering by sending a serialcommand.Data accumulation begins according tothe buffering mode selected. Measure-ment data accumulates in the memory ofthe sensor.Wait until data accumulation iscompleted. You can check the status byreading the accumulation status with theserial command RTS.Stop buffering by sending a serialcommand. Data accumulation will bestopped.YesNoPC (Host device)Is accumulationcompleted?(1) Send settings(2) Buffering start(3) Accumulationstart(4) Status check(5) Buffering stop(6) Accumulateddata readoutBuffering modeThere are two modes for buffering, "Continuous" and "Trigger". The default setting is "Con-tinuous".With "Continuous", buffering the measurement data begins when the sensor head receivesthe start command and continues until either the amount of data to accumulate has beenreached or the sensor receives a stop command.1 2Accumulation of measurement data Measuring1 Data buffering starts2 The amount of data to be accumulated has been reached or the sensor has received a stop command.Rugghölzli 2CH - 5453 BusslingenTel. +41 (0)56 222 38 18Fax +41 (0)56 222 10 12mailbox@sentronic.comwww.sentronic.comProdukte, Support und ServiceSENTRONIC AG