HL-G1 User's Manual 4.4 Function Settings85t Function480ms Save (see page 46)530ms Laser ON (see page 78)580ms Laser OFF (see page 78)4.4.10.1 Zero SetBy inputting the MI signal for 30ms you set the current measurement value and the digitaldisplay to zero.There are two other ways to perform a zero set: In run mode, press and together Send the serial command RZSFor information on how the zero-set signal influences the system behavior, refer to the timediagrams (see page 33).4.4.10.2 ResetBy inputting the MI signal for 80ms you reset all measurement values and turn the judgmentoutputs off. NOTE When the reset signal is input, the output data status becomes undefined(see page 31). The analog output will either be the initial value of 11.000 [V]or 21.6 [mA] or a predefined fixed value, depending on the setting of "Ana-log Output Selection" (see page 66). When you perform the reset by sending the serial command RRS, the mem-ory will be cleared.There are two other ways to perform a reset: In run mode, press and together Send the serial command RRSFor information on how the reset signal influences the system behavior, refer to the time dia-grams (see page 33).Rugghölzli 2CH - 5453 BusslingenTel. +41 (0)56 222 38 18Fax +41 (0)56 222 10 12mailbox@sentronic.comwww.sentronic.comProdukte, Support und ServiceSENTRONIC AG