Parker EME Setting up Compax3192-120114 N5 C3I22T11 June 2008 1554.2 Configuring the signal SourceIn this chapter you can read about:Select signal source for Gearing ......................................................................................1554.2.1. Select signal source for GearingIn this chapter you can read about:Signal source HEDA.........................................................................................................156Encoder A/B 5V, step/direction or SSI feedback as signal source...................................156+/-10V analog speed setpoint value as signal source ......................................................158Here the signal source is configured for the motion function ”Gearing” (electronicgearbox).Available are:Gearing input signal source The HEDA real-time bus (M10 or M11 option) directly from a Compax3 masteraxis an encoder signal A/B 5V a step/direction signal 5V or a velocity as analog value +/-10VHEDA operating mode HEDA as MasterUnder signal source gearing "not configured" must be set!If an existing HEDA option (M10 or M11) is not used as signal source, you cantransmit the following signals for a slave axis via HEDA: Process - setpoint position (Object 2000.1) Process - actual position (Object 2200.2) Position from external setpoint (object 2020.1)Signal read in via Analog channel0 (X11/9 and X11/11), encoder input or step /direction input in the master.Principle:HEDA HEDAEncoder Master Slave SlaveStep / Direction+/-10VCompax3Compax3Compax3