Setting up Compax3 C3I22T11240 192-120114 N5 C3I22T11 June 20084.3.5. Input simulationIn this chapter you can read about:Calling up the input simulation .........................................................................................240Functionality .....................................................................................................................241The input simulation is used for the performance of tests without the complete in-put/output hardware being necessary.The digital inputs (standard and inputs of M10/M12 option) as well as the analoginputs are supported.The following operating modes are available for digital inputs: The physical inputs are deactivated, the digital inputs are only influenced via theinput simulation. The digital inputs and the physical inputs are logically or-linked.This necessitates very careful action, as the required function is, above all withlow-active signals, no longer available.The pre-setting of an analog input value is always made in addition to the physicalanalog input.the function of the inputs depends on the Compax3 device type; please refer to therespective online help or the manual.The input simulation is only possible if the connection with Compax3 isactive and if the commissioning mode is deactivated!4.3.5.1 Calling up the input simulationOpen the optimization window (double klick in the C3 ServoManager tree entry:Optimization).Activate the Tab ”Setup” in the right lower window.Clicking on the following button will open a menu; please select the input simulati-on.Function