Communication C3I22T11300 192-120114 N5 C3I22T11 June 20085.2 COM port protocolIn this chapter you can read about:RS485 setting values........................................................................................................300ASCII - record...................................................................................................................301Binary record ....................................................................................................................302You can communicate with Compax3 in order to read or write objects via plug X10( or X3 on the mains module of Compax3M) on the front via a COM port (max. 32nodes).As a rule 2 records are possible: ASCII record simple communication with Compax3 Binary record: fast and secure communication with Compax3 by the aid of blocksecuring.Switching between the ASCII and the binary record via automatic recorddetection.interface settings (see page 406)RS232: SSK1 (see page 383)RS485: like SSK27 (see page 384) / RS485 is activated by +5V on X10/1.USB: SSK33/03 (only for Compax3M)5.2.1. RS485 setting valuesIf ”Master=Pop” was selected, only the settings compatible with the Pops (ParkerOperator Panels) made by Parker are possible.Please note that the connected Pop has the same RS485 setting values.You can test this with the "PopDesigner" software."Master=General" makes all Compax3 settings possible.You can use this address to allow the master to access multiple devices simulta-neously.The device address of the connected Compax3 can be set here.Adjust the transfer speed (baud rate) to the master.Please choose between two-wire and four-wire RS485 (see page 60).Adjust the protocol settings to the settings of your master.WiringMulticast AddressDevice AddressBaud rateConnection TypeProtocol