Modem Information Rack X page MIB variables description 198Model 1001MC Operations Guide 9 • Model 3088RC managementFigure 98. Web page navigation to Slot Configuration PageFor more information about items on the Slot Configuration page, see “Slot Configuration page MIB variablesdescription” on page 209.Modem Information Rack X page MIB variables descriptionThis section describes the MIB variables that are available on the Modem Information Rack X page. Startingfrom the HOME page, click on the following links: Home (menu) > Configure Cards (menu) > View Rack [racknumber].Slots Available (totalConfigSlots)Displays the number of configurable slots available in the rack.Modems Installed (rackXCardsInstalled)Displays the number of modem cards installed in the rack that the system has found.Number of Power Supplies (rackXPowerSupplies)This is where you specify the number of power supplies installed in the rack (this value determines the addressingrange for the rack). In the case of a redundant power supply system, you should set this variable to 2, this willinform the Model 1001MC that there should be 2 power supplies in the system.Rack Protection Mode (rackXProtected)If you want to protect all Model 3088RC rack cards installed in the current rack from being globally config-ured, select protected(1) from the drop-down menu, then click the Submit button. For more information aboutthe system configuration feature, refer to section “System Config” on page 259.