Model 1094 Configuration—Next Configuration page MIB variables description 84Model 1001MC Operations Guide 5 • Model 1094ARC managementModel 1094 Configuration—Next Configuration page MIBvariables descriptionThe Model 1094 Configuration—Next Configuration page enables you to update the configuration of the1094ARC NetLink-HDSL modems that are installed in the system. After making changes to the configurationon this page, select Back to return to the Model 1094 Configuration Slot page, then select onLine as the InputMode, and finally, select Submit Query to send the new information to the Model 1001MC over the network.Note If the NetLink-HDSL modems are not connected, and changes madeto the remote configuration will be lost after the units link-up. Allparameters in the Local column can be changed at any time.The following sections describes the MIB variables that are available on the Model 1094 Configuration—NextConfiguration page.Card Address (nmsSlotID)Displays the address of the selected NetLink-HDSL modem.Line Status (lineStatus1094)This variable displays the status of the line. There are three possible values that can be displayed:• startup(1)• dataMode(2)—In this mode, the units are linked-up and ready to send data• testMode(3)Processor Mode (processorMode1094)This variable displays the status of the processor running on the NetLink-HDSL. There are four values that aresignificant to you:• normal(0)—When the processor is in normal(0) mode, the NetLink - HDSL modem is monitoring itselfand sending the status information to the Model 1001MC• internalProcessing(1)—When the processor is in the internalProcessing(1) mode, it is either busy down-loading code to the internal DSP or setting the data pump.• negotiating(2)—When the processor is in the negotiating(2) mode, the card was just brought online andthe NetLink-HDSL is setting up the configuration parameters within the Model 1001MC.• lineDown(3).At startup, all of the fields will be highlighted in yellow, signifying that they are not verified parameters. As theNetLink-HDSL sets up the parameters, the highlighting disappears, signifying that the display matches the set-ting of the card.Local Software Rev (softVersion1094)These read-only MIB variable displays the current version of code that is running in the NetLink-HDSL rackcard modem. You should check the download web page to see if the Model 1001MC has a newer version ofcode available for downloading. Through the download web page, you can update the software that is runningin the NetLink-HDSL rack card.