Chapter 3 Configuring Your LibraryConfiguring System SettingsScalar i500 User’s Guide 129Enable SNMP V1/V2 3 Enables Simple Network Management Protocol (SNMP) V1 and V2cservices to run on the library. This option is disabled by default.Enable IPv6 3 Enables support for IPv6. This option is disabled by default.The path to open the appropriate screen is as follows:• From the operator panel, select Setup > System Settings.Enable SMI-S 3 Enables the SMI-S service to run on the library. This setting is disabled bydefault.The path to open the appropriate screen is as follows:• From the operator panel, select Setup > System Settings.Unlabeled MediaDetection 3 At bootup and other times the library performs an inventory of all slotsand media. If a slot contains media with an unreadable barcode label (forexample, the label is missing, torn, or marked up), the scanner cannotidentify it, so the library normally reports the slot as empty.With the Unlabeled Media Detection feature, you can configure thelibrary to detect and report which slots contain media with unreadablebarcodes. Since cartridges with unreadable barcodes will not work forNote: SNMP v3 is always enabled. For more information onSNMP, see Configuring SNMP Settings on the Library onpage 63.Note: This setting differs from opening the SNMP port in theTools > Security menu (see Configuring Library SecuritySettings on page 124). In order to run SNMP, the port mustbe open and the SNMP service must be enabled.Note: This setting differs from opening the SMI-S port in theTools > Security menu (see Configuring Library SecuritySettings on page 124). In order to run SMI-S, the port mustbe open and the SMI-S service must be enabled.