PLC-WTC500L Expand Serial Command Functional Specifications26/758.6.3 CF_INPUT 1 CommandCommand “CF_INPUT1_%1” [CR]%1“HDMI” ----------------------------- Select HDMI Input“ANALOG” ------------------------ Select PC Analog Input“SCART” --------------------------- Select SCART InputDetails Select Input 1 as well as Source specified in %1 (Available only in the normalPower ON status)Response Acceptable “000” [CR]Unacceptable “Error Code” [CR]8.6.4 CF_INPUT 2 CommandCommand “CF_INPUT2_%1” [CR]%1“VIDEO” ---------------------------- Select Composite Video Input“YPBPR” --------------------------- Select Y,Pb/Cb,Pr/Cr Input“YCBCR” --------------------------- Select Y,Pb/Cb,Pr/Cr Input“ANALOG” ------------------------- Select RGB InputDetails Select Input 2 as well as Source specified in %1. (Available only in the normalPower ON status)Response Acceptable “000” [CR]Unacceptable “Error Code” [CR]8.6.5 CF_INPUT 3 CommandCommand “CF_INPUT3_%1” [CR]%1 “VIDEO” ---------------------------- Select Composite Video Input“S-VIDEO” ------------------------- Select S-Video InputDetails Select Input 3 as well as Source specified in %1.(Available only in the normal Power ON status)Response Acceptable “000” [CR]Unacceptable “Error Code” [CR]8.6.6 CF_INPUT 4 CommandCommand “CF_INPUT4_%1” [CR]%1 “NETWORK” ----------------------- Select input from PJ-NetDetailsSelect Input 4 as well as Source specified in %1. (Available only in the normalPower ON status)*With PJ-Net unattached, this command is invalid and error code “103” is returned.*With PJ-Net attached and the power OFF, error code “101” is returned.Response Acceptable “000” [CR]Unacceptable “Error Code” [CR]