PLC-WTC500L Expand Serial Command Functional Specifications68/759.11.13 CR_STANDBYMODE CommandCommand “CR_STANDBYMODE” [CR]Details Get setting status of Standby modeResponseAcceptable “000_%1” [CR]%1 “ECO” --------------------------- Eco mode is selected“NORMAL” --------------------- Normal mode is selectedUnacceptable “Error Code” [CR]9.11.14 CR_P-MANE CommandCommand “CR_P-MANE” [CR]Details Get setting status of Power managementResponseAcceptable “000_%1” [CR]%1“OFF” ------------------------ Power Management is disabled“READY” -------------------- Power Management is set to Ready“SHUTDOWN” ----------- Power Management is set to ShutDown modeUnacceptable “Error Code” [CR]9.11.15 CR_P-MANETIME CommandCommand “CR_P-MAETIME” [CR]Details Get setting time for starting Power Management functionResponseAcceptable “000_%1” [CR]%1 “001 – 030” ----------------------- 1 to 30 minutesUnacceptable “Error Code” [CR]9.11.16 CR_ON-STA CommandCommand “CR_ON-STA” [CR]Details Get setting status of Power ON StartResponseAcceptable “000_%1” [CR]%1 “ON” -------------------------- Power ON Start is ON“OFF” ------------------------ Power ON Start is OFFUnacceptable “Error Code” [CR]9.11.17 CR_FANSPEED CommandCommand “CR_FANSPEED” [CR]Details Get selected Fan Control Speed mode.ResponseAcceptable “000_%1” [CR]%1 “MAX” ------------------------ Max mode is selected“NOR” ------------------------ Normal mode is selectedUnacceptable “Error Code” [CR]