PLC-WTC500L Expand Serial Command Functional Specifications61/759.9 Lamp Status Read Command9.9.1 CR_LAMPREPL CommandCommand “CR_LAMPREPL” [CR]Details Get information of Lamp Replacement timeResponseAcceptable “000_%1” [CR]%1“2Y” ----------------- indicates over lamp replacement time“2N” ----------------- indicates under lamp replacement time“2” means the number of lamps(2 lamp is used→ “2”)“Y”/”N” means if it is time to replace lamp or not.Example:“2Y” ----- 2 lamps is used and it is over lamp replacement timeUnacceptable “Error Code” [CR]9.9.2 CR_LAMPH CommandCommand “CR_LAMPH” [CR]Details Get Lamp running time (in hours)* return actual lamp running timeResponseAcceptable “000_%1_%2” [CR]%1_%2Lamp 1 data comes first, and then one space, after that lamp2 data is followed.%1 = lamp No.1%2 = lamp No.2eg; “00410_00410” [CR]▪▪▪▪ → Lamp No.1 = 410 HoursLamp No.2 = 410 HoursNote;-each data shall be 5 digits.Unacceptable “Error Code” [CR]9.9.3 CR_LAMPCORRESPH CommandCommand “CR_LAMPCORRESPH” [CR]Details Get Lamp running time (in hours)*return lamp running time multiplied by a coefficient (not actual running time)ResponseAcceptable “000_%1_%2” [CR]%1_%2Lamp 1 data comes first, and then one space, after that lamp2 data is followed.“00000 – 99999” ▪▪▪▪ %1= Lamp No.1“00000 – 99999” ▪▪▪▪ %2= Lamp No.2Unacceptable “Error Code” [CR]