PLC-WTC500L Expand Serial Command Functional Specifications62/759.9.4 CR_LAMPMODE CommandCommand “CR_LAMPMODE” [CR]Details Get setting status of Lamp controlResponseAcceptable “000_%1” [CR]%1“AUTO1” ------------------ Lamp control is Auto1“AUTO2” ------------------ Lamp control is Auto2“HIGH” -------------------- Lamp control is High“NORMAL” --------------- Lamp control is Normal“ECO1” ------------------- Lamp control is Eco1“ECO2” ------------------- Lamp control is Eco2Unacceptable “Error Code” [CR]9.9.5 CR_LAMPSTS CommandCommand “CR_LAMPSTS” [CR]Details Get the information of Lamp lighting statusResponseAcceptable “000_%1” [CR]%1“2**”The first character indicates 2 lamps are used in this model.The following characters indicate each lamp status in lampnumber order as showed below.“I” ------------------------ Lamp is ON“O” ---------------------- Lamp is OFF“X” ----------------------- Lamp Failuree.g.“2IO” ------------------- This indicates it is 2-lamps system,Lamp #1 is ON, and #2 is OFF.Unacceptable “Error Code” [CR]9.9.6 CR_PROJH CommandCommand “CR_PROJH” [CR]Details Get total running time of Projector (in hours)ResponseAcceptable “000_%1” [CR]%1 “0000000 – 0099999”Unacceptable “?” [CR]9.9.7 CR_HMLAMP CommandCommand “CR_HMLAMP” [CR]Details Get total lamp numberResponseAcceptable “000_%1” [CR]%1 “002”Unacceptable “Error Code” [CR]