PLC-WTC500L Expand Serial Command Functional Specifications73/759.12 Other Status Read Commands9.12.1 CR_STATUS CommandCOMMAND “CR_STATUS” [CR]Detail Get operating status of ProjectorSame as “CR0” in basic command except error code follows it.ResponseAcceptable “000_%1” [CR]%1“00” = Power ON“80” = Standby“40” = Countdown in process“20” = Cooling Down in process“10” = Power Failure“28” = Cooling Down in process due to abnormal temperature“88” =Standby after Cooling Down due to abnormaltemperature“24” = Power Save/Cooling Down in process“04” = Power Save“21” = Cooling Down in process after turned Off due to lampfailure“81” Standby after Cooling Down due to lamp failure“2C” = Cooling Down in process after Power Off due toShutter management“8C” = Standby after Cooling Down due toShutter managementUnacceptable “Error Code” [CR]9.12.2 CR_SIGNAL CommandCommand “CR_SIGNAL” [CR]Details Get status whether there is any signal or not.ResponseAcceptable “000_%1” [CR]%1 “ON” -------------------------- There is signal“OFF” ------------------------- There is no signalUnacceptable “Error Code” [CR]9.12.3 CR_VMUTE CommandCommand “CR_VMUTE” [CR]Details Get setting status of Shutter.ResponseAcceptable “000_%1” [CR]%1 “ON” ---------- Video mute is ON(Shutter close)“OFF” --------- Video mute is OFF(Shutter open)Unacceptable “Error Code” [CR]9.12.4 CR_FREEZE CommandCommand “CR_FREEZE” [CR]Details Get setting status of Freeze.ResponseAcceptable “000_%1” [CR]%1 “ON” --------------------- Freeze is ON“OFF” -------------------- Freeze is OFFUnacceptable “Error Code” [CR]