1 - 94Chapter 3 Removal and Replacement Procedures (RRPs)RRP6.1 ROS ASSEMBLY (PL 6.1)When performing the ROS ASSEMBLY removal and/or installation, be sure to performthe operation on a level and smooth work surface. If the operation is performed on arough and/or inclined surface, the ROS ASSEMBLY will be out of alignment.Removal1) Remove the COVER REAR 500 (PL 7.2) (RRP7.9).2) Remove the COVER REAR (PL 1.1) (RRP1.1).3) Remove the COVER LEFT (PL 1.1) (RRP1.3).4) Remove the COVER RIGHT (PL 1.1) (RRP1.2).5) Remove the COVER EXIT 500 (PL 1.1) (RRP7.1).6) Remove the 500 EXIT ASSEMBLY (PL 7.1) (RRP7.2).7) Remove the COVER TOP (PL 1.1) (RRP1.4).8) Remove the COVER FRONT (PL 1.1) (RRP1.5).9) Remove the DUCT FRONT (PL 6.1) (RRP6.2).10) Remove the 3 screws (silver with flange, 8mm) securing the DUCT HIGH (PL 9.1), and remove theDUCT HIGH (Figure 1).11) Remove the screw (silver with flange, 8mm) securing the DUCT VACUUM L/R (PL 6.1), andrelease the hooks of the DUCT VACUUM L/R, and remove the DUCT VACUUM L/R.12) Release the 2 clamps holding the harnesses, from the PLATE TIE FRONT (PL 9.1) (Figure 1).13) Remove the 8 screws (silver, 6mm) securing the PLATE TIE FRONT to the frame, and remove thePLATE TIE FRONT (Figure 1).14) Release the 2 clamps holding the harnesses, from the ROS ASSEMBLY (Figure 1).15) Disconnect 4 connectors of the HARNESS ASSEMBLY ROS (PL 6.1) (Figure 1).Figure 1. ROS Assembly