Phaser 3010/3040/WorkCentre 3045 Service Xerox Internal Use Only 4-3Service Parts DisassemblyPreparationBefore you begin any procedure:WarningUnplug the power cord from the wall outlet.WarningAllow the Fuser to cool before using the procedure.CautionMany parts are secured by plastic tabs. Do not over flex or force these parts.Do not over torque screws threaded into plastic.NoteNames of parts that appear in the removal procedures may not match thenames that appear in the Parts List. For example, a part called Paper Tray in aremoval procedure may appear on the Parts List as Cassette, Assy. While usingremoval procedure, ignore any prerequisite procedures for parts alreadyremoved.1. Wear an Electrostatic Discharge wrist strap.2. Turn Off power and disconnect the power cord from the wall outlet.3. Disconnect all cables from the printer.4. Remove the Toner Cartridges (page 4-5).Notations in the Disassembly Text• The notation “(item X)” points to a numbered callout in the illustrationcorresponding to the disassembly procedure being performed.• The notation “PLX.X.X” indicates the component is listed in the Parts List.• Arrows in an illustration show direction of movement when removing orreplacing a component.• The notation “(tap, plastic, 10 mm)” or “(metal, 6 mm)” refer to the type ofscrew being removed.Replacement NoteProvides information specific to the replacement of parts or assemblies.