Index-Sub Type RW Default Value range Unit Description0x8200-01 S16 R/W** 2 -32768 …32767Configuration quick stopÄ ‘Explanation of the elements’ on page 92Ä Chapter 4.9 ‘Brake control’ on page 73The object contains the action to be used at a Quick stop.Mode Description0 Instant state change to ‘Switch on disabled’1 reserved2 Break with quick stop deceleration 0x8580-03 and subsequent state changeto ‘Switch on disabled’4... reservedIndex-Sub Type RW Default Value range Unit Description0x8200-05 S16 R/W** 2 0 … 2 Configuration fault reactionÄ ‘Explanation of the elements’ on page 92The object contains the action to be used on an error of the System SLIO motion module.Mode Description0 Instant state change to ‘Switch on disabled’1 reserved2 Break with 0x8580-03 and subsequent state change to ‘Switch on disabled’4... reserved5.2.10 Operating modes - 0x8280Index-Sub Type RW Default Value range Unit Description0x8280-00 U08 R 2 2 Operating mode - number of entriesÄ ‘Explanation of the elements’ on page 920x8200-01 - Configurationquick stop0x8200-05 - Configurationfault reaction0x8280-00 - Operatingmode - number of entriesVIPA System SLIO Object dictionaryObjects > Operating modes - 0x8280HB300 | FM | 054-1DA00 | en | 18-06 111