4.16.4 Configuration of the System SLIO motion moduleParameters for the operationOperating mode: PositioningPulse shape: Incremental encoder simulation (A/B), suitable to the setting of thepower stageCoupling motion module to power stage: 1:1User unit: 0.01mmTraverse due to the mechanics:with r: revolutions® 2000 units ≙ Traverse path of 20mmPosition limits: ±6000mm®Max. Motor speed:®Required max. Acceleration:®Required max. Deceleration:®Specific I/O signals of the power stage: Controlling and evaluation is done via the System SLIO motionmoduleVIPA System SLIODeploymentExample: 054-1DA00 with YASKAWA Sigma 5 mini > Configuration of the System SLIO motion moduleHB300 | FM | 054-1DA00 | en | 18-0688