Index-Sub Type RW Default Value range Unit Description0x8580-03 S32 R/W** 10000 10 …100000000[user] Deceleration quick stop valueÄ ‘Explanation of the elements’ on page 92This object specifies the value of the target deceleration in case of a quick stop.Index-Sub Type RW Default Value range Unit Description0x8580-04 S32 R/W** 10000 10 …100000000[user] Acceleration limitÄ ‘Explanation of the elements’ on page 92This object indicates the bidirectional limit value for the set point acceleration value. Eachset point acceleration value is checked against this limit value. Please note that the lowerlimit is unequal 0. As soon as a set point velocity value is active, the movement starts,although the set point acceleration is 0.Index-Sub Type RW Default Value range Unit Description0x8580-06 S32 R/W** 10000 10 …100000000[user] Deceleration limitÄ ‘Explanation of the elements’ on page 92This object indicates the bidirectional limit value for the set point deceleration value. Eachset point deceleration value is checked against this limit value. Please note that the lowerlimit is unequal 0. As soon as a set point velocity value is active, the movement starts,although the set point deceleration is 0.5.2.16 Voltages - 0x8680Index-Sub Type RW Default Value range Unit Description0x8680-00 U08 R 19 19 Voltages - number of entriesÄ ‘Explanation of the elements’ on page 920x8580-03 - Decelerationquick stop value0x8580-04 - Accelerationlimit0x8580-06 - Decelerationlimit0x8680-00 - Voltages -number of entriesVIPA System SLIOObject dictionaryObjects > Voltages - 0x8680HB300 | FM | 054-1DA00 | en | 18-06122