INSTRUMENT DESCRIPTIONAxio Vert.A1 Technical Specifications Carl Zeiss05/2012 431030-7044-001 232.4 Technical SpecificationsDimensionsDimensions (Width x Depth x Height)Axio Vert.A1 ....................................................................................... 235 mm * x 560 mm x 560 mmAxio Vert.A1 FL or A1 FL-LED...........................................................235 mm * x 560 mm*** x 560 mmAxio Vert.A1 MAT ......................................................................... 220 mm ** x 560 mm *** x 355 mm* Equipped with fixed stage without object guide** Without mechanical stage; with 40 mm x 40 mm mechanical stage: Width: 295 mm*** Depth: 560 mm, without external (reflected light) illuminatorsThe above measurements are maximum dimensions, which include space for cable and connector outlets. Thedepth was measured at an interpupillary distance of 62 mm, with binocular parts lowered.Transmitted light LED illumination results in the height of transmitted light stands being reduced by 29 mm.Weight****Axio Vert.A1 Stand ................................................................................................................10.5 kgAxio Vert.A1 FL-LED Stand ......................................................................................................12.3 kgAxio Vert.A1 FL Stand ............................................................................................................11.7 kgAxio Vert.A1 MAT Stand ........................................................................................................10.3 kg**** Actual weight of the stand without any attachments, such as stages, tubes, etc.Ambient ConditionsShipping (in Packaging):Permissible ambient temperature ...............................................................................-40 °C to +70 °CStorage:Permissible ambient temperature ................................................................................+5 °C to +40 °CMaximum permissible humidity (without condensation)................................................. 75 % at 35 °COperation:Permissible ambient temperature ................................................................................+5 °C to +35 °CMaximum permissible humidity (without condensation)............................................... 75 % at +35 °CMaximum altitude for use ......................................................................................................2,000 mAtmospheric pressure .........................................................................................800 hPa to 1,060 hPaPollution degree ............................................................................................................................... 2Operating SpecificationsOperating environment ................................................................................................... Enclosed spacesSafety class .............................................................................................................................................IDegree of protection ....................................................................................................................... IP 20Electrical safety ..................................................................As specified in DIN EN 61010-1 (IEC 61010-1),taking into account CSA and UL regulationsOvervoltage category .............................................................................................................................IIRadio interference suppression .......................................................... As specified in EN 55011 for Class BNoise immunity ....................................................................................... As specified in DIN EN 61326-1AC line voltage range ................................................................................. 100 VAC to 240 VAC ±10 %Line frequency ..................................................................................................................50 Hz to 60 HzMaximum power consumption of internal power supply unit ......................................................... 80 VA