2. When prompted by the Operator Control Panel display and the I/O Stationopens, insert a blank or scratch data cartridge.3. Close the I/O Station by pushing it back into the library.4. While the test is running, the Operator Control Panel will display library status.v If the test PASSES, resume normal library operations.v If the test FAILS, an error code will be displayed. Make note of the error,then refer to Chapter 7, “Troubleshooting,” on page 7-1.Note: Library Verify requires a piece of scratch media to perform the test. Oncethe test has been initiated, the user must complete the test.5. When prompted by the Operator Control Panel display and the I/O Stationopens, remove the cartridge used in the test.6. Close the I/O Station by pushing it back into the library.7. Use the Up/Down keys to highlight . Press the Select key to exit theLibrary Verify screen.Service: Run TestsThe following library diagnostics are available in this menu:v System Test - this test exercises library components by moving customer datacartridges from slots to drives and back to slots. No data is written or read fromthe customer tapes. To run this test successfully, the library must contain at leastone data cartridge for every drive present in the library.v Slot to Slot Test - The Slot To Slot test will move each resident data cartridgefrom one slot to another, for each test cycle requested. When completing the SlotTo Slot test, you will need to Inventory your library before placing it backonline, since this test scrambles the cartridge slot locations.Note: After running the System Test or the Slot to Slot Test, the library will needto be re-inventoried. It might be required to reboot the library after librarydiagnostics completes to ensure proper library re-detection on somebackup applications.Service: Service (Drives)ServiceRun Testsa77ug048Figure 5-23. Service: Run Tests menuChapter 5. Operations 5-31