8 Technical Data8.3 Rating data138 DE1 variable speed starter 09/14 MN040011EN www.eaton.comPower sectionRated operationcurrentI e A 6.6 8.5 11 16Overload current,1.5 x I e, cyclically for60 s every 600 sI 2-150 A 9.9 12.75 16.5 24Overload current,max. 2 x I e every600 sI 2max A 13.2 17 22 32Output voltage at U e U 2 V 400/480, 3-phase 400/480, 3-phase 400/480, 3-phase 400/480, 3-phaseOutput Frequency f2 Hz 0 - 50/60(max.300)0 - 50/60(max. 300)0 - 50/60(max. 300)0 - 50/60(max. 300)Frequency resolution(reference value)Δf % 0.025 0.025 0.025 0.025Pulse frequency(audible)f PWM kHz 16 (10/12/14/16/18/20)16 (10/12/14/16/18/20)16 (10/12/14/16/18/20)16 (10/12/14/16/18/20)Derating between 50 °Cand 60 °CNone None • None iffPWM ≦ 16 kHz• None ifIe ≦ 10.6 A andfPWM ≦ 20 kHz• None up to amax. of 57 °C• None iff PWM ≦ 14 kHzup to a max. of50 °C• None iff PWM ≦ 16 kHzup to a max. of46 °C• None ifIe ≦ 14.9 A andf PWM ≦ 10 kHz• None ifIe ≦ 10.6 A andf PWM ≦ 20 kHzMax. leakage current toearth (PE)I PE mA < 3.5 AC/< 10 DC < 3.5 AC/< 10 DC < 3.5 AC/< 10 DC < 3.5 AC/< 10 DCDC braking 0 - 100 % Ue, 0 - 10 s, parameterizableHeat dissipationSpeed/torque100/100 P v W 90 120 159 24090/100 P v W 87 116 154 233100/50 P v W 51 73 82 14390/100 P v W 50 71 89 13850/100 P v W 80 93 136 21850/50 P v W 50 70 67 14750/25 P v W 48 52 64 860/100 P v W 79 93 129 1900/50 P v W 41 58 74 1210/25 P v W 38 48 60 81Symbol Unit DE1-346D6… DE1-348D5… DE1-34011… DE1-34016…