4-6 Data subject to change without notice 7/07. © 2007 GE DrivesThe function code consists of alphanumeric characters with unique letters assigned to each function group.Table 4-3-1Function Code Function RemarksF00 - F42 Fundamental functionsE01 - E47 Terminal Extension FunctionsC01 - C33 Frequency Control FunctionsP01 - P09 Motor ParametersH03 - H39 High Performance FunctionsA01 - A18 Alternative Motor Parameterso01 - o29 Optional Functions Can only be selected with an option connectedTo scroll the Function Select screen rapidly, use + or + to move the screen as a unit sortedalphabetically.Select the desired function and press FUNCDATA to switch to the Data Setting screen.On the Data Setting screen, the data values on the LCD can be increased or decreased in the smallest possible unit bypressing or . Holding down or causes the values to increase or decrease more rapidly. Other-wise, select the digit to be modified using and then set data directly. When data is modified, the value beforemodification will be displayed at the same time for reference purpose. To save the data, press FUNCDATA . Pressing cancelsthe changes made and returns control to the Function Select screen. The modified data will be effective in inverteroperation after the data has been saved by FUNCDATA . If the data is not saved, there is no change to the inverter operation.When data setting is disabled in the case of “Data protected” or “Data setting invalid during inverter running,” make thenecessary changes as indicated in Table 4-3-2 below.Table 4.3.2Display Reason for No Modification Release MethodLINK ACTIVE Currently writing from RS-485 / RTU option tofunction is being madeSend a cancel command to function writing from RS-485 RTU. Stops a “write” operation from the linkcommunication option.NO SIGNAL(WE) The edit enabling command function is selectedusing a general-purpose input terminalFor functions E01 to E09, turn data terminal 19 (editenabling command selection) ONDATA PRTCTD Data protection is selected for function F00. Change function F00 to 0INV RUNNING An attempt was made to change a function thatcannot be changed during inverter operation.Stop inverter operationFWD/REV ON An attempt was made to change a function thatcannot be changed with the FWD/REV commandon.Turn FWD/REV command offF00 DATA PRTCF01 FREQ CMD 1F02 OPR METHODF03 MAX Hz-1F00 DATA PRTCF01 FREQ CMD 1F02 PPR METHODF03 MAX Hz-1F42 TRQ VECTOR 1E01 X1 FUNCE02 X2 FUNCE03 X3 FUNCA18 SLIP COMP 2F00 DATA PRTCF01 DATA PRTCF02 OPR METHOD+ +